Accurex T4 Fast Test Kit
Accurex T4 Fast Test Kit
Couldn't load pickup availability
Accurex T4 Fast Test Kit T4 is the most commonly measured substance in the assessment of thyroid function. Elevated total thyroxine levels have been associated with hyperthyroidism, a condition with an excess amount of circulating thyroid hormone and decreased total thyroxine levels associated with hypothyroidism, a condition with insufficient levels of thyroxine concentration. The test uses anti-human T4 monoclonal antibody conjugated with fluorescence latex coated on the junction of nitrocellulose membrane and sample sad, and T4 antigen coated on the test line. After the sample has been applied to the test strip, the fluorescence latex-labelled anti-human T4 monoclonal antibody binds with the T4 in the sample and forms marked antigen-antibody complex. The complex moves to the detection zone by capillary action, which is then captured on the test line by the T4 antigen. The fluorescence intensity of the test line increases in proportion to the amount of T4 in the sample. Then Insert the test card into AccuDxCQ Immunofluorescence Quantitative Analyzer/Automatically inserted by AccuDxCQ Immunofluorescence Quantitative Analyser (hereafter referred to as AccuDx CQ), the concentrations of T4 in the sample will be measured and displayed on the screen. The value will be stored in AccuDx CQ and available for downloading. The result can be easily transmitted to the laboratory or hospital information systemUses:It is intended for in vitro quantitative determination of T4 in serum and plasma. It can be used in monitoring hyperthyroidism and hypothyroidism and as an aid in the functional diagnosis of the thyroidProduct Specifications and Features:
Content: AccuDx CQ T4 test card with desiccant (25), disposable pipet (25), blood sample diluent (1), sd card (1), user manual (1)
It stores the values, which are available in downloadable form
These values are displayed on the screen, which can be transmitted to the laboratory or hospital information system
Easy to use and operate
Directions For Use:
Collect specimens according to the manual
Test card, sample and reagent should be brought to room temperature prior to testing
Confirm SD card lot no. in accordance with test kit lot no. perform “SD card calib” calibration when necessary (details refer to 8.5.2of Getein1100 user manual)
On the main interface of Getein1100, press the "ENT" button to enter the testinginterface
Remove the test card from the sealed pouch immediately before use. Label the test card with patient or control identification
Put the test card on a clean table, horizontally placed
Using a sample transfer pipette, deliver 100 ?l of sample into one tube of sample diluent, and mix gently and thoroughly. Then drop 100 ?l (or three drops of the sample when using a disposable pipet) of sample mixture into the sample port on the test card
After 10 minutes, insert the test card into Getein1100 and press the "ENT" button
The result will be shown on the screen
Safety Information:
Read the label carefully before use
Store in a cool and dry place, away from sunlight
Keep out of reach of children
Store the test card at 4-30 degree Celcius with a valid period of 24 months
Use the test card within 1 hour once the foil pouch is opened
Store the blood sample diluent at 0-30 degree Celcius for a valid period of 24 months
Store the blood sample diluent at 2-8 degree Celcius for better results
For in vitro diagnostic use only
For professional use only
Do not use the kit beyond the expiration date
Do not use the test card if the foil pouch is damaged
Do not open pouches until ready to perform the test
Do not reuse the test card
Do not reuse the pipet
Handle all specimens as potentially infectious
Proper handling and disposal methods should be followed in accordance with local regulations
Carefully read and follow the manual to ensure proper test performance
Composition :