Accurex Biomedical Pvt. Ltd
Accurex D-Dimer Fast Test Kit
Accurex D-Dimer Fast Test Kit
Couldn't load pickup availability
Accurex D-Dimer Fast Test Kit uses an anti-human D-Dimer monoclonal antibody conjugated with fluorescence latex and another anti-human D-Dimer monoclonal antibody coated on the test line. After the sample has been applied to the test strip, the fluorescence latex-labelled anti-human D-Dimer monoclonal antibody binds with the D-Dimer in sample and forms a marked antigen-antibody complex. This complex moves to the test card detection zone by capillary action. Then marked antigen-antibody complex is captured on the test line by another anti-human D-Dimer monoclonal antibody. The fluorescence intensity of the test line increases in proportion to the amount of D-Dimer in sample. Then insert test card into Getein1100 Immunofluorescence Quantitative Analyzer (hereafter referred to as Getein1100), the concentration of D-Dimer in sample will be determined and displayed on the screen. The value will be stored in Getein1100 and available for downloading. The result can be easily transmitted to the laboratory or hospital information system.Uses:It is intended for in vitro quantitative determination of D-Dimer in plasma or whole blood. The test is used as an aid in the assessment and evaluation of patients suspected of deep-vein thrombosis or pulmonary embolism.Product Specifications and Features:
It is intended for in vitro quantitative determination of D-Dimer in plasma or whole blood
The test is used as an aid in the assessment and evaluation of patients suspected of deep-vein thrombosis or pulmonary embolism
It has 25 tests
Directions For Use:
Collect specimen according to manual
Test card, sample and reagent should be brought to roomtemperatureprior to testing
Confirm SD card lot No. in accordance with test kit lot No. Perform“SDCard Calib” calibration when necessary
On the main interface of Getein1100, press "ENT" button to enter testinginterface
Remove the test card from the sealed pouch immediately beforeuse. Label the test card with patient or control identification
Put the test card on a clean table, horizontally placed
Using sample transfer pipette, deliver 100 ?l of sample into onetubeof sample diluent, mix gently and thoroughly. Then drop 100 ?l (or 3dropsof sample when using disposable pipet) of sample mixture into thesampleport on the test card
After 10 minutes, insert the test card into Getein1100 and press "ENT" button
The result will be shown on the screen
Safety Information:
For in vitro diagnostic use, only
For professional use only
Do not use the kit beyond the expiration date
Do not use the test card if the foil pouch is damaged
Do not open pouches until ready to perform the test
Do not reuse the test card
Do not reuse the pipet
Handle all specimens as potentially infectious
Proper handling anddisposal methods should be followed in accordance with local regulations
Carefully read and follow the manual to ensure proper test performance
Composition :
Share